MEGOHMMETER 1000V CAT. III & 600V CAT. IV
Characteristics
Item name | MEGOHMMETER 1000V CAT. III & 600V CAT. IV |
---|---|
EAN code | 3700461471568 |
Intro |
Specially designed for hybrid and electric vehicles, this device can measure the isolation of electrical equipment, as well as a voltage up to 1000V. It allows the measurement of DC and AC voltage, DC and AC current, temperature, resistance, capacity, isolation and frequency. |
Text | Suitable for the "low voltage" requirements of authorisations: BCL, B2VL, B2TL, B2XL ... |
Product highlight | Suitable for hybrid and electric vehicles |
Specifications |
Specifications: Complies with IEC/EN 61010-1 1000V CAT III, 600V CAT IV. 1000V DC Voltage, 750V AC Voltage (TRMS). - DC voltage: 600mV-6V-60V-600V-1000V - AC voltage 600mV-6V-60V-600V-750V - DC current: 60mA-400mA - AC current: 60mA-400mA - 6600 counts (except for capacity, temperature and insulation measurement) - when the input terminals are V and COM, the protective voltage overload is up to 250V AC (TRMS). - when the input terminals are mA and COM, the protection current is 0.4A. - when the input terminals are Hi and Lo, the protective voltage overload is 600V. - display of minimum average values - 4 AA batteries (NEDA 15A or IEC LR6) for 1000 hours of battery life for the insulation test. - the multimeter can perform at least 1000 insulation tests with new alkaline batteries at room temperature. These are standard tests of 1000V in 1MΩ with a duty cycle of 5 seconds on and 25 seconds off. - resistance: 600ohm-6kohm-60kohm-600kohm-6Mohm-60Mohm - insulation measurement range: 0.01MΩ to 2GΩ. - isolation test voltages: 50V, 100V, 250V, 500V, 1000V. - insulation original voltage: +20%, -0%. - insulation short circuit test current: 1.5mA nominal. - automatic discharge of insulation: Discharge time <1 second for C = 1μF or lower. - detection of the live isolation circuit: block the test if the voltage at the terminal is >20V before starting the test. - insulation resistance: 50V (5-50Mohm) - 100V (0-100Mohm) - 250V (0-250Mohm) - 500V (0-500Mohm) - 1000V (0-2Gohm) - calculation of dielectric absorption ratio (DAR) and automatic polarization index (PI); - maximum capacitive load of insulation: operates up to a load of 1μF. - storage temperature: -40°C to 60°C. - operating temperature: 0°C to 40°C. - storage altitude: 12000m - operating altitude: 2000m 1000V CAT III, 3000m 1000V CAT II - temperature: -30 to 1300°C - temperature coefficient: 0.05 (specified accuracy) per °C for temperatures <18°C or >28°C. - relative humidity: 40%~75%. - dimensions: 205(L) 102(W) 58(H)mm. - weight: about 390g. - electrical safety categories: CAT III 1000V, this device can be used in a category 3 medium (shown in the table on the left) at a maximum voltage of 1000V, and in a category 4 medium at a maximum voltage of 600V. |
Contents |
Contents: - 1x Megohmmeter - 1x pair of measuring cables - 1x pair of crocodile clips - 1x MS 3204 - 1x temperature probe (Thermocouple type K) - 1x transport house - 1x transport strap (shoulder strap) - 4x LR6 batteries |
Warranty period | 2 years |
Tension | 1000V |
More | Powered by battery |
Cable length | 1.20 m |
Length | 205.00 mm |
Width | 102.00 mm |
Height | 58.00 mm |
Tariff code | Tariff Normal (TN) |
Warranty Procedure | DIAGNOSTIC |
Customer benefit | This isolation controller complies with the standard and quality expectations of CESVI France. |